Our company produce vertical turbine pump,vertical long axis pump, vertical type condensate pump ,vertical wet pit pump,right Angle gear box.
Date:2022/7/16 22:11:08
Views:
Removal of RV-SP Landfill Leachate Pump
1. Remove motor or fixing plate and outlet pipe.
2. Remove volute and impeller nut, pry back of impeller lightly and remove key impeller.
3. Remove the driven coupling, then remove the key, and then remove the motor base, and separate it from the support barrel.
4. Remove the pump seat and support cylinder bolts to separate them.
5. Remove the sleeve and bearing from the shaft.